2024 Heatinghelp.com the wall - The most common wall height for homes in the United States is 8 feet. Some luxury homes have walls that are 9 or 10 feet high, while some older homes have walls only 7 feet high.

 
Sometimes you may want to take an office or home space and temporarily change the layout for a specific purpose. Collapsible partition walls make it easy to do so. You can change the space again and again without making any permanent and ex.... Heatinghelp.com the wall

Learn how to tell if a wall is load bearing with our step-by-step guide. Avoid costly mistakes by identifying load bearing walls before making renovations. Expert Advice On Improving Your Home Videos Latest View All Guides Latest View All R...HeatingHelp.com is committed to industry education and thrives on the spirit of shared knowledge and community. Here are some of the many resources you’ll find here: The Wall discussion forum - Got a question? Ask it here. Everyone is welcome to join in, pros and homeowners alike, and the conversations go back decades. I've rarely heard anything good about any home warranties. 1) Their goal is not to actually repair the problem correctly, but to get it working to reach the end of the warranty. Analogy, you need knee replacement, but the insurance company just keep giving you ibuprofen and a fancy knee brace and says this is fine, knowing it will hold you off ... @SethYank that looks like a standard return elbow. Unless we're missing something, this is an Orifice Vapor system. The orifice is located in the radiator shutoff valve, and is sized to keep the radiator from filling more than 85% or so at a certain boiler pressure.I have a client who this last summer removed his radiator to tile the wall behind it. They called me out to figure why the upstairs (2nd floor) radiators are not heating. Bled upstairs radiators and did not get any air. My thoughts are its flow-locked. I was going to close off all the first floor radiator valves to force flow upstairs, hopefully. Hi all, I need some input on how gas meters are sized because I think mine is technically undersized for the load. My meter says it's rated for 250 CFH @ 0.5" diff. My current loads are : WH : 40. Boiler : 125. Clothes dryer : 30. Kitchen range : 50 (5 burners + oven)We would like to show you a description here but the site won’t allow us. Description: HeatingHelp: The Wall is a forum for heating professionals to share tips and advice. The site includes forums, articles, product reviews, and more. Some of the top news sources that talk about HVAC trends? 1. Heating, Air Conditioning, Refrigeration News (HVACR) 2. The Air Conditioning, Heating & Refrigeration News (AHR)84.6K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 Biomass; 421 Carbon Monoxide Awareness; 56 Chimneys & Flues; 1.8K Domestic Hot Water; 4.9K Gas Heating; 123 Geothermal; 157 Indoor-Air Quality; 3.1K Oil Heating; 57 Pipe Deterioration; 826 Plumbing; 5.6K Radiant Heating; 373 Solar; 14.2K Strictly Steam ; 3.1K Thermostats and Controls ... Switch to single pipe or use a deaerator, install a two micron secondary filter ( Wix 33528 or equivalent). If you have to or want to change pump, try a Beckett PF20323. Bulletin about this issue attached, it's a fuel degradation problem and …The Wallies at HeatingHelp.com were talking about pipe recently. One guy asked a question about why some pipe sizes are skipped. “For instance,” he said. “Why …Dec 3, 2023 · Heating in my house is not working. psethia Member Posts: 1. December 3. https://ibb.co/cDnfGCs. Hello, The heating in my house stopped working a few weeks ago. I called a contractor who said that my circulating motor is shot and replaced it. Hydrostat 3250 plus Code 8. matthewA Member Posts: 1. October 25. I have a Hydrostat 3250 plus stuck with a number 8 on the screen. I've tried powering off and on. Doesn't change. Can't find any trails on this matter. I have a Hydrostat 3250 plus stuck with a number 8 on the screen.A Timeline of HeatingHelp.comA visual timeline of how HeatingHelp.com has looked over the years. Read the full story here ... One of the things, @JUGHNE, which makes The Wall dangerously nearly unique, if not actually unique, is that the core contributors -- the real pros (and they know who they are) -- are not in it to demonstrate how clever ...January 2022. A licensed plumber's crew installed a new water heater three weeks ago. The hot water smelled like oil for a couple of weeks. It's lessened now, but I suspect it's still there somewhere and I worry about this. I'm a senior woman alone and I need advice. I also worry about an effect on my health.Hi, I have a DIY copper coil heat exchanger wrapped around the flue of my wood stove, which passively circulates to a standard electric domestic hot water tank. I feel it is a safe design, with multiple TP relief valves, pressure gauge, an air bleeder and drain valves. In the coldest weeks of the winter, I often find that I use my wood stove ...Nov 26, 2023 · Details. 1144 sq ft Ranch over unheated full basement built to minimal 'Contractor' standards in 1973 on Cape Cod, MA. Currently heated with a 25 year old 100,000 BTU +/- Burnham cast iron boiler through 60' of Slant Fin baseboard. I have run heat loss calcs on Heatload.net and come up with heating load of 27,000 BTU so per Slant Fin these ... John Williams from the Carrier Group for getting his engineering degree. But the most exciting news; is that his little girl came out of the heart surgery and will get to come home soon. His daughter had a hole in her little heart and they had to go in and fix it again. Hey folks lets all give John a big congratts and a prayer for his little girl.DL Mechanical LLC Heating, Cooling and Plumbing 732-266-5386 NJ Master HVACR Lic# 4630 Specializing in Steam Heating, Serving the residents of New JerseyIt is ALL low PH. It creates incredible problems in heating and domestic hot water systems. If you have water with a low PH, you will have worse copper damage than from "softened" water. "Hard" water usually means that a lot of dissolved solids in the water. It can be calcium, magnesium and iron along with other things.Got a general heating question, or a comment to make? Just want to chat with friends? This is the place. « 1 … 864 865 866 867 868 869 870 … 1703 » Adjusting Flow Check Valves. Mike Lampkin_2 Member Posts: 124. April 2007. I'm curious to find out if most manufacturers flow checks are built to the same specs or not. I have come across some that are tricky to adjust. When the flow check is turned down too tightly it won't open when the circ starts and when turned up too much the flow check ...Apr 27, 2019 · HeatingHelp 1.6K views 12 comments 2 points Most recent by DanHolohan April 28 THE MAIN WALL Replacement Steam Boiler- Gas vs. Oil, Power Vent vs. Chimney apaul1018 312 views 12 comments 0 points Most recent by ethicalpaul April 28 Strictly Steam Dec 7, 2023 · 55 Water Quality. 645 Buy, Sell, Barter. 42 Industry Classes. 84 Job Opportunities. 26 Recall Announcements. Find Us on YouTube. Subdural’s TriumphMany extremely capable women are tackling tough jobs in mechanical rooms despite pushback. Read the full story here. HeatingHelp.com is the place to go to get all of your heating questions answered. “The Wall” is a forum for all things heating and when you contribute, chances are high that your knowledge will be shared via the HeatingHelp.com blog. Each day is precious. And more…. You can reach Dan directly at: [email protected] 10, 2023 · Heating Pros: Please Help Us With This Quick Survey. Erin Holohan Haskell Member, Moderator, Administrator Posts: 2,171. October 10 edited October 12 in THE MAIN WALL. If you're a heating professional, we'd love your help answering this 2-minute survey on Modcon Boiler Life vs. Cast Iron Boiler Life. You can access the survey here. While it is impossible to know exactly what the Great Wall of China cost to build, modern calculations estimate the cost to be approximately $360 billion. The wall is 4,160 miles from end to end.Stucco is a popular choice for exterior wall finishes due to its durability, versatility, and attractive appearance. If you’re considering stucco for your home or building, one question that may come to mind is how long the process takes fr...January 2020. Had a new Weil-McLain Ultra 105 Series 3 boiler installed November 3, 2017. We use propane. Worked great for two years. On December 23, 2019 it wasn't maintaining temperature. Repair guy,who installed it, came and looked at it and couldn't figure out what was wrong with it. He talked to tech support and was told it needed a …Dec 6, 2023 · Then let the boiler run for a week or so and if it's got brown water again, drain it and reapply 8-way again. Repeat this a few times if needed until most or all of the sedimented rust/mud has broken free. Then fill it once again, and add enough 8-way until the PH is 10-11 and let it ride for the rest of the season. Dec 7, 2023 · 55 Water Quality. 645 Buy, Sell, Barter. 42 Industry Classes. 84 Job Opportunities. 26 Recall Announcements. Find Us on YouTube. Subdural’s TriumphMany extremely capable women are tackling tough jobs in mechanical rooms despite pushback. Read the full story here. Description: HeatingHelp: The Wall is a forum for heating professionals to share tips and advice. The site includes forums, articles, product reviews, and more. Some of the top news sources that talk about HVAC trends? 1. Heating, Air Conditioning, Refrigeration News (HVACR) 2. The Air Conditioning, Heating & Refrigeration News (AHR)A permit will be pulled when the time comes. EBEBRATT-Ed Member Posts: 14,538. March 2022. In MA. there are no permits required specifically for the boiler and the boiler piping which is considered heating and is not plumbing. Plumbers are not licensed to do heating in MA. That being said:The Wall discussion forum - Got a question? Ask it here. Everyone is welcome to join in, pros and homeowners alike, and the conversations go back decades. The Search …About Us. HeatingHelp.com is a vibrant online community and reliable resource for heating information. We’ve been connecting the industry since 1997. If you’re interested in heating systems, no matter how old or new, you’re sure to find the answers you need here. HeatingHelp.com is committed to industry education and thrives on the spirit ... Don't forget that nozzles are rated and stamped at 100PSI. The point being, sometimes, especially if you're burning cold oil, a smaller nozzle, that is one that is rated at less gpm run at a higher pressure to get the desired firing rate will atomize better. Steadier flame, less impingement, and less chance for big droplets to escape the pattern.HeatingHelp 4.1K views 67 comments 1 point Most recent by PanchoLippincott December 9 THE MAIN WALL. ... 84.7K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 …A Timeline of HeatingHelp.comA visual timeline of how HeatingHelp.com has looked over the years. Read the full story here ... One of the things, @JUGHNE, which makes The Wall dangerously nearly unique, if not actually unique, is that the core contributors -- the real pros (and they know who they are) -- are not in it to demonstrate how clever ...The Brookhaven lab tests show that the EK is the most efficient oil burner boiler there is, surpassing even the three pass designs. It's not a complicated setup. Any good tech shouldn't have a problem working on it. If it has to be oil, it has to be EK! What is the best boiler out of these three: New Yorker fr-122-w, Burnham RSAH 85TH, or Weil ...High Temp lLight. RS25 Member Posts: 1. November 2021. EBEBRATT-Ed Member Posts: 14,600. STEVEusaPA Member Posts: 6,395. Just installed a Biasi B10/5. The high temp is set at 180, the low temp is set at 140. The boiler heats up past the 180 setting and the high temp light comes on.Installed Dec. 2005. Standing pilot. Gas / hot water. High Limit Switch Honeywell L4080D1036. Transformer Relay R8285D-1000. Limit switch was set at 180F. Pressure/temp gauge on boiler showed boiler turning on at 105F off at 125F. I now have switch set all the way to 240F. Boiler on at 130F off at 145F.18,000- 30,000 btu/hr according to my HDS software calc 18,000 at a 20 degree delta T, 1.8 gpm 140F average temperature, 1/2 pex 3.2FPS, 9.8 feet of head per 100' of tubeDon't forget that nozzles are rated and stamped at 100PSI. The point being, sometimes, especially if you're burning cold oil, a smaller nozzle, that is one that is rated at less gpm run at a higher pressure to get the desired firing rate will atomize better. Steadier flame, less impingement, and less chance for big droplets to escape the pattern.February 2007. As Ken stated, by some accounts comparing Viessmann and Crown are one in the same. Everone thinks the big V engineers all their products from the ground up and is vastly superior in their designs, if you take a look at the Rondomat by Viessmann and the Crown series 32 boiler the are exactly the same, Viessmann aquired the design ...Paul Pollets Member Posts: 3,648. May 2013. Plaster Ceiling Radiant. I've seen leaks where the copper tubing was tied to the lattice with stove wire, creating a dielectric current and corrosion. Plaster alkalyds are also corrosive to the piping, but ceiling systems seem to last longer than copper embedded in concrete.84.7K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 Biomass; 421 Carbon Monoxide Awareness; 58 Chimneys & Flues; 1.8K Domestic Hot Water; 5K Gas Heating; 124 Geothermal; 158 Indoor-Air Quality; 3.2K Oil Heating; 57 Pipe Deterioration; 832 Plumbing; 5.7K Radiant Heating; 373 Solar; 14.3K Strictly Steam ; 3.1K Thermostats and …October 2022. If you can jump the thermostat connections at the gas valve and it works and then jump at the thermostat and it doesn't work doesn't necessarily mean its a bad wire. It could be a dirty or bad thermocouple. Its only generating a very small voltage. To put it in perspective it is .001 of a volt. 84.7K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 Biomass; 421 Carbon Monoxide Awareness; 58 Chimneys & Flues; 1.8K Domestic Hot Water; 5K Gas Heating; 124 Geothermal; 158 Indoor-Air Quality; 3.2K Oil Heating; 57 Pipe Deterioration; 830 Plumbing; 5.6K Radiant Heating; 373 Solar; 14.3K Strictly Steam ; 3.1K Thermostats and Controls; 55 ...I have call for 143,000 BTU heating capacity, and the PEG 187 is 151,000 BTU. The new boiler is 82% efficient as well. Anyway, I live close to Utica (Rochester, NY), I have run in a 15k in Utica (the Utica Boilermaker), and parts are easy to get.Nov 15, 2023 · 84.6K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 Biomass; 421 Carbon Monoxide Awareness; 56 Chimneys & Flues; 1.8K Domestic Hot Water; 5K Gas Heating; 123 Geothermal; 157 Indoor-Air Quality; 3.1K Oil Heating; 57 Pipe Deterioration; 827 Plumbing; 5.6K Radiant Heating; 373 Solar; 14.2K Strictly Steam ; 3.1K Thermostats and Controls; 55 ... Adjusting Flow Check Valves. Mike Lampkin_2 Member Posts: 124. April 2007. I'm curious to find out if most manufacturers flow checks are built to the same specs or not. I have come across some that are tricky to adjust. When the flow check is turned down too tightly it won't open when the circ starts and when turned up too much the flow check ...Dec 6, 2023 · Systems Help Center. Our comprehensive HVAC Systems Help Center covers a wide range of HVAC-related topics, including air conditioning and heat pumps, geothermal, hot-water heating, thermostats and controls, solar, steam heating, and warm air. We also have a section of informative and entertaining articles to help you sharpen your HVAC business ... January 2005 in THE MAIN WALL. I have a question regarding a Dovre wood burning fireplace insert. We recently purchased a house built in 1994. it has a very nice Dovre fireplace insert model 2100 or 2108 with no. 9622440 on the nameplate. There is no owners manual and we would like to know more about the operating instructions.84.7K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 Biomass; 421 Carbon Monoxide Awareness; 58 Chimneys & Flues; 1.8K Domestic Hot Water; 5K Gas Heating; 124 Geothermal; 158 Indoor-Air Quality; 3.2K Oil Heating; 57 Pipe Deterioration; 830 Plumbing; 5.6K Radiant Heating; 373 Solar; 14.3K Strictly Steam ; 3.1K Thermostats and …Dec 7, 2023 · 55 Water Quality. 645 Buy, Sell, Barter. 42 Industry Classes. 84 Job Opportunities. 26 Recall Announcements. Find Us on YouTube. Subdural’s TriumphMany extremely capable women are tackling tough jobs in mechanical rooms despite pushback. Read the full story here. In my experience wether it be baseboard or slab heat 1/2-1 gpm will satisfy most properly piped terminal units or heat loops, I don’t think these would be any different. That being said once it is roughed in and buried behind painted walls, it’s not a mistake you ever want to make. the heat system- Is 2ea Lochinvar knight 199s 10ea pumped ...There are no elbows in any loop - the loops attach to a rehau manifold with rehau actuators. My system is heated by my 75 gal domestic hot water heater which has ports for radiant heat. The entire system is at floor level. The distance from the heat source to the manifold is approx. 15 feet and will have approximately 8 elbows in the one inch ...Help finding 1-1/4 x 3/4 Cast Iron / Steel Monoflo Diverter Tees. sixplex 61 views 2 comments Most recent by sixplex November 3.There are no elbows in any loop - the loops attach to a rehau manifold with rehau actuators. My system is heated by my 75 gal domestic hot water heater which has ports for radiant heat. The entire system is at floor level. The distance from the heat source to the manifold is approx. 15 feet and will have approximately 8 elbows in the one inch ...Dec 2, 2023 · A better way is a boiler with an Indirect water heater. But the boiler still has to work to make hot water in the indirect tank. My personal opinion is to have a dedicated water heater. Gas, Electric Resistance, Heat Pump, whatever. This way, when the boiler is down for whatever reason, you still have hot water. One of the things, @JUGHNE, which makes The Wall dangerously nearly unique, if not actually unique, is that the core contributors -- the real pros (and they know who they are) -- are not in it to demonstrate how clever they are, or how professional, but come here with a genuine desire to help, as best they can, all comers. Yes, there are times ... About Us. HeatingHelp.com is a vibrant online community and reliable resource for heating information. We’ve been connecting the industry since 1997. If you’re interested in heating systems, no matter how old or new, you’re sure to find the answers you need here. HeatingHelp.com is committed to industry education and thrives on the spirit ... HeatingHelp 316 views 15 comments 1 point Most recent by ethicalpaul November 27. ... 84.7K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 Biomass; 421 Carbon ... HeatingHelp.com is committed to industry education and thrives on the spirit of shared knowledge and community. Here are some of the many resources you’ll find here: The Wall discussion forum - Got a question? Ask it here. Everyone is welcome to join in, pros and homeowners alike, and the conversations go back decades. Art has long been appreciated for its ability to stimulate the senses and evoke emotions. But did you know that art can also have a positive impact on productivity in the workplace? In this article, we will explore the benefits of incorpora...We would like to show you a description here but the site won’t allow us. Aug 23, 2023 · He said my house needed plenty of hot water since it has baseboard heat and that the savings with a high-efficiency boiler get eaten up the 1st time you have to have a maintenance call. He quoted me around $ to $ for one with slightly higher efficiency. He said the cast-iron would last 30 years whereas the high efficiency would be more like 10-15. Dannex, which is a low temp radiant baseboard requires baseboard on both exterior and interior to get enough heat in a room. As you may have noticed, all the old gravity hot air systems had the heat registers on the interior walls and the returns on the exterior walls because that was how the natural convection worked best.You are the expert ...Got a general heating question, or a comment to make? Just want to chat with friends? This is the place. « 1 … 1693 1694 1695 1696 1697 1698 1699 … 1702 »credit to The Notorious. The Buderus G115WS/3 literature calls it a "low temperature" boiler, but in the fine print of the installation manual, it says that for systems containing large water volumes (>115 gal per MBTU), a bypass valve must be installed to redirect some of the hot supply water back into the return to maintain boiler water temps ...Sometimes you just don't need a giant safe to hide your belongings in, which is why Instructables user The King of Random put together a guide to hiding you smaller stuff inside a wall outlet. Sometimes you just don't need a giant safe to h...A boiler is considered a continuos load so a 15 amp breaker can supply a 12 amp load. A 20 amp breaker can feed a 16 amp load. nicholas bonham-carter Member Posts: 8,576. August 2020. Some newer boilers, and A/C’s are particular about the the quality of A/C current Produced, so try it out first before cutting the check.—NBC.There are no elbows in any loop - the loops attach to a rehau manifold with rehau actuators. My system is heated by my 75 gal domestic hot water heater which has ports for radiant heat. The entire system is at floor level. The distance from the heat source to the manifold is approx. 15 feet and will have approximately 8 elbows in the one inch ...One of the things, @JUGHNE, which makes The Wall dangerously nearly unique, if not actually unique, is that the core contributors -- the real pros (and they know who they are) -- are not in it to demonstrate how clever they are, or how professional, but come here with a genuine desire to help, as best they can, all comers. Yes, there are times ... I suspect you might need the thermostatic valve for return water protection. The way that system is going to run, if you have the right t-stat on it set up correctly is it will call on temp and more or less shut off on heat anticipator so it will keep the system at a somewhat constant temp that matches the heat loss of the structure.Not long ago, Ray asked the Wallies who post daily on The Wall at HeatingHelp.com what advice they would give someone just starting out in this business. Here’s some of what …Adding radiant floor to existing baseboard hydronic heating system. 241comp 84 views 10 comments Most recent by hot_rod 12:26AM.84.6K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 Biomass; 421 Carbon Monoxide Awareness; 58 Chimneys & Flues; 1.8K Domestic Hot Water; 5K Gas Heating; 123 Geothermal; 157 Indoor-Air Quality; 3.1K Oil Heating; 57 Pipe Deterioration; 829 Plumbing; 5.6K Radiant Heating; 373 Solar; 14.2K Strictly Steam ; 3.1K Thermostats and …Let us not forget the fact that many areas of the country and different government entities do not require licenses to do what we do. So, work like this and worse! is allowed to happen. 1. All Categories. 84.6K THE MAIN WALL. 3K A-C, Heat Pumps & Refrigeration. 54 Biomass. 421 Carbon Monoxide Awareness.Art has long been appreciated for its ability to stimulate the senses and evoke emotions. But did you know that art can also have a positive impact on productivity in the workplace? In this article, we will explore the benefits of incorpora...Flames are much lower now. And now it takes about 9 minutes after the inital start up for the pressure to build to 2.5 psi before pressuretrol shuts off the boiler and still 2.5 minutes for psi to drop to about .5 for boiler to start. This compare to 3 minutes to build up to 2.5 psi and 2.5 minutes to drop to .5 psi.Heatinghelp.com the wall

January 2022. A licensed plumber's crew installed a new water heater three weeks ago. The hot water smelled like oil for a couple of weeks. It's lessened now, but I suspect it's still there somewhere and I worry about this. I'm a senior woman alone and I need advice. I also worry about an effect on my health.. Heatinghelp.com the wall

heatinghelp.com the wall

Sep 22, 2023 · The L bracket allow you to be spaced off the wall about 2 1/2 inches . Personally I’m not a big fan of tapcons when given a choice cherry rivets lead shielded nail ins ,expansion or wedge anchors they all have there place it’s like sheet rock screws for screwing 3/8 plates duh sheet rock Oi. The Lost Art of Steam Heating Revisited. $49.99. Classic Hydronics: How to Get the Most From Those Older Hot-Water Heating Systems. $24.88. The Contractor Stories. $25.00. A Pocketful of Steam Problems (With Solutions!) $25.00. Pumping Away: And Other Really Cool Piping Options for Hydronic Systems. HeatingHelp.com is the place to go to get all of your heating questions answered. “The Wall” is a forum for all things heating and when you contribute, chances are high that your knowledge will be shared via the HeatingHelp.com blog. Each day is precious. And more…. You can reach Dan directly at: [email protected] lot has changed since we operated that gas station. But the fuel is still the same. Diesel is #2 fuel and home heating oil is #2 fuel. Same stuff different dye. If in a pinch, you can also use kerosene or #1 fuel (or A1 Jet fuel if near an airport) in a pinch. Usually more expensive and also less BTU per gallon.Hi all, I need some input on how gas meters are sized because I think mine is technically undersized for the load. My meter says it's rated for 250 CFH @ 0.5" diff. My current loads are : WH : 40. Boiler : 125. Clothes dryer : 30. Kitchen range : 50 (5 burners + oven)US Post Office, Ridley Park PA. 2205 sf collector area for space heating and cooling. This building was completed in 1976. The building was featured in Kaiman Lee's Encyclopedia of energy-efficient building design: 391 practical case studies. The solar panels provided 20% of the post office's heating and cooling energy needs.US Post Office, Ridley Park PA. 2205 sf collector area for space heating and cooling. This building was completed in 1976. The building was featured in Kaiman Lee's Encyclopedia of energy-efficient building design: 391 practical case studies. The solar panels provided 20% of the post office's heating and cooling energy needs.Aug 23, 2023 · He said my house needed plenty of hot water since it has baseboard heat and that the savings with a high-efficiency boiler get eaten up the 1st time you have to have a maintenance call. He quoted me around $ to $ for one with slightly higher efficiency. He said the cast-iron would last 30 years whereas the high efficiency would be more like 10-15. I am working on finishing our basement, and putting warmboard-R. Am working on getting the bathroom roughed in, putting dricore under the boilet, shower, and bathtub, coming out 50" from the outer wall. Then placing the warmboard-R in the 54" floor space.Because my clay flue is rectangular 6" x 10", I will be forced to use ovalized smooth wall heavy gauge 316Ti stainless liner. My breach is 7" and I must maintain that size to the wall. But the chimney liner CAN be downsized by 1 size to 6". To have 1/2" clearance to the terra cotta tiles, that means the ovalized pipe would need to be 5" x 9".I don't think I have a good way to power vent out a side wall. My basement is a granite block lined hole, with timber frame sills on top, then living space. No good place to put a hole anywhere near the furnace. The nearest wall that would work would be 30 feet away, and then I'd need to go through a cement foundation, turning a corner or two.For the homemade version it would depend on the pipe size as to how well it would work. I didn’t show the vent in my model. Won't work, except for the stand pipe that has the vent on it. Steam will flow to the vent and close it and the air will be compressed and trapped in the top half of the other stand pipes. A chronological archive of posts similar to the oil tech talk and firedragon have. Your existing archive is fantastic, but the advantage of having a chronological archive in addition--based on the most recent post date--would be that those of us pro and HO alike could know where to look if we missed a week of the Wall.The Contractor Stories. $25.00. A Pocketful of Steam Problems (With Solutions!) $25.00. Pumping Away: And Other Really Cool Piping Options for Hydronic Systems. $24.64. As …Hi all, I need some input on how gas meters are sized because I think mine is technically undersized for the load. My meter says it's rated for 250 CFH @ 0.5" diff. My current loads are : WH : 40. Boiler : 125. Clothes dryer : 30. Kitchen range : 50 (5 burners + oven)Dec 7, 2023 · 55 Water Quality. 645 Buy, Sell, Barter. 42 Industry Classes. 84 Job Opportunities. 26 Recall Announcements. Find Us on YouTube. Subdural’s TriumphMany extremely capable women are tackling tough jobs in mechanical rooms despite pushback. Read the full story here. A retaining wall is a wall built especially to hold back something like rocks or water. While it’s used in industry, it also can help make a garden layout look beautiful and aesthetically pleasing. Making your own is possible with a few sim...Dec 3, 2023 · Heating in my house is not working. psethia Member Posts: 1. December 3. https://ibb.co/cDnfGCs. Hello, The heating in my house stopped working a few weeks ago. I called a contractor who said that my circulating motor is shot and replaced it. A permit will be pulled when the time comes. EBEBRATT-Ed Member Posts: 14,538. March 2022. In MA. there are no permits required specifically for the boiler and the boiler piping which is considered heating and is not plumbing. Plumbers are not licensed to do heating in MA. That being said:If you were to purchase a packaged boiler most will have the pump on the return side. It would be very rare to have any issues caused by pump location on a low head system. The correct location (and our recommendation) is on the supply side of the system, pumping away from the expansion tank.@SethYank that looks like a standard return elbow. Unless we're missing something, this is an Orifice Vapor system. The orifice is located in the radiator shutoff valve, and is sized to keep the radiator from filling more than 85% or so at a certain boiler pressure.oil-2-4-6-gas. Posts: 206. February 2005. Aero. No, the Aero is it's own design. The Brooker Bros. are still at their plant in Ontario making burners, it's just that Brad-White are the bosses now. Another good source for Aero parts is Crown Engineering . www.crownengineering.com.The Lost Art of Steam Heating Revisited. $49.99. Classic Hydronics: How to Get the Most From Those Older Hot-Water Heating Systems. $24.88. The Contractor Stories. $25.00. A Pocketful of Steam Problems (With Solutions!) $25.00. Pumping Away: And Other Really Cool Piping Options for Hydronic Systems.Dec 6, 2023 · Then let the boiler run for a week or so and if it's got brown water again, drain it and reapply 8-way again. Repeat this a few times if needed until most or all of the sedimented rust/mud has broken free. Then fill it once again, and add enough 8-way until the PH is 10-11 and let it ride for the rest of the season. A cement wall gives your yard extra privacy, helps you define your outdoor spaces and can add a unique look to your home. If you’re willing to put in the time, you can construct your own retaining wall from cement blocks. This guide shows y...The other solution suggested was that I should use a different anti-freeze chemical. Methyl alcohol used to be used. It's not as effective as glycol and I don't think this would be a good idea for a heating system. I tried getting some advice from the anti-freeze suppliers in the UK, but I got nowhere. It seemed that they get their business ...For the homemade version it would depend on the pipe size as to how well it would work. I didn’t show the vent in my model. Won't work, except for the stand pipe that has the vent on it. Steam will flow to the vent and close it and the air will be compressed and trapped in the top half of the other stand pipes.84.7K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 Biomass; 421 Carbon Monoxide Awareness; 58 Chimneys & Flues; 1.8K Domestic Hot Water; 5K Gas Heating; 124 Geothermal; 158 Indoor-Air Quality; 3.2K Oil Heating; 57 Pipe Deterioration; 831 Plumbing; 5.7K Radiant Heating; 373 Solar; 14.3K Strictly Steam ; 3.1K Thermostats and Controls; 55 ...Aug 23, 2023 · He said my house needed plenty of hot water since it has baseboard heat and that the savings with a high-efficiency boiler get eaten up the 1st time you have to have a maintenance call. He quoted me around $ to $ for one with slightly higher efficiency. He said the cast-iron would last 30 years whereas the high efficiency would be more like 10-15. Heating Help: The Wall. The #1 Online Resource for Heating Answers. Ask and answer questions about heating systems, both old and new. Welcome! Here are the website …Aug 23, 2023 · He said my house needed plenty of hot water since it has baseboard heat and that the savings with a high-efficiency boiler get eaten up the 1st time you have to have a maintenance call. He quoted me around $ to $ for one with slightly higher efficiency. He said the cast-iron would last 30 years whereas the high efficiency would be more like 10-15. 84.6K THE MAIN WALL; 3K A-C, Heat Pumps & Refrigeration; 54 Biomass; 421 Carbon Monoxide Awareness; 56 Chimneys & Flues; 1.8K Domestic Hot Water; 4.9K Gas Heating; 123 Geothermal; 157 Indoor-Air Quality; 3.1K Oil Heating; 57 Pipe Deterioration; 826 Plumbing; 5.6K Radiant Heating; 373 Solar; 14.2K Strictly Steam ; 3.1K Thermostats and Controls ... Just bought a house/office that was built in 2005, boiler installed in 2005 I have 10,000 square feet of finished space with Hot Water Baseboard heat.Wiring TACO SR502-4. In the process of redoing my 2 zone radiant heating system I've added a secondary circulator along with the 2 primaries. As I understand it the secondary will come on along with either or both primary circulators as needed. I'm using a Taco SR502-4 switching relay and would like to know if there is a way to wire it to ...September 2004. Getting a new oil fired boiler. Old oil line in cement floor. Oil tank in basement. Is it better to have the new oil line run along the floor or go from the tank up to the joists, then run overhead, then run down to the burner? If we run the oil line along the floor, it will run mosly along outside and inside walls in the basement.Hi all, I need some input on how gas meters are sized because I think mine is technically undersized for the load. My meter says it's rated for 250 CFH @ 0.5" diff. My current loads are : WH : 40. Boiler : 125. Clothes dryer : 30. Kitchen range : 50 (5 burners + oven)January 2005. I have oil inside my burner housing that is dripping onto the blower fan and getting flicked everywhere inside the burner. The transformer foam and CAD cell is saturated with oil. I've had this problem a few times in the past at servicing time and have taken the burner apart and cleaned it up and it was clean for a year or so each ...For the homemade version it would depend on the pipe size as to how well it would work. I didn’t show the vent in my model. Won't work, except for the stand pipe that has the vent on it. Steam will flow to the vent and close it and the air will be compressed and trapped in the top half of the other stand pipes.The most common wall height for homes in the United States is 8 feet. Some luxury homes have walls that are 9 or 10 feet high, while some older homes have walls only 7 feet high.The wall has a lot of resources Browse the library here lots of very old, and new data to browse interesting stuff. Post an add in find a contractor. Heatinghelp.com is the first web site to pop up when searching the web for heating help. 0. This discussion has been closed. Categories. All Categories;End switch. On a call for heat [a signal from the thermostat] the zone control, or zone valve "makes", this allows the zone valve to open or the circulator to start. When zone valve or other actuator "strokes open" the end switch "makes" and sends a signal to the burner TT terminals to start the burner. An end switch is usually a " dry contact ...There are no elbows in any loop - the loops attach to a rehau manifold with rehau actuators. My system is heated by my 75 gal domestic hot water heater which has ports for radiant heat. The entire system is at floor level. The distance from the heat source to the manifold is approx. 15 feet and will have approximately 8 elbows in the one inch ...The oven short circuit and will not fire up. I have a Reed rotator oven all of the sudden the motor for the rotating shelves stopped working we open the side panel to check why the motor wasn’t rotating. One of my employees accidentally tripped the fuse that between the burner control and the temperature switch now we lost the heat.THE MAIN WALL. Home › THE MAIN WALL. Welcome! Here are the website rules, as well as some tips for using this forum. Need to contact us? Visit https://heatinghelp.com/contact-us/. Click here to Find a Contractor in your area. « 1 2 3 4 5 6 7 … 1703 ». Using chemical additives to clean the boiler, questions. Looking at the corrosion in the above photo, where is the oxygen coming from? Or do you suppose this is from caustic attack. Saying no to chemicals without any knowledge of regional water supply chemistry or knowing whether the pH is properly controlled makes for a fairly dogmatic …Don't forget that nozzles are rated and stamped at 100PSI. The point being, sometimes, especially if you're burning cold oil, a smaller nozzle, that is one that is rated at less gpm run at a higher pressure to get the desired firing rate will atomize better. Steadier flame, less impingement, and less chance for big droplets to escape the pattern.Apr 27, 2019 · HeatingHelp 1.6K views 12 comments 2 points Most recent by DanHolohan April 28 THE MAIN WALL Replacement Steam Boiler- Gas vs. Oil, Power Vent vs. Chimney apaul1018 312 views 12 comments 0 points Most recent by ethicalpaul April 28 Strictly Steam January 2005. I have oil inside my burner housing that is dripping onto the blower fan and getting flicked everywhere inside the burner. The transformer foam and CAD cell is saturated with oil. I've had this problem a few times in the past at servicing time and have taken the burner apart and cleaned it up and it was clean for a year or so each ...Help finding 1-1/4 x 3/4 Cast Iron / Steel Monoflo Diverter Tees. sixplex 61 views 2 comments Most recent by sixplex November 3. Yes you can braze over solder. If the tubing and joint are old clean them as much as possible and then braze. Getting the water out so you can get the joint hot enough will be the issue. Ed. Scott Kneeland Member Posts: 158. August 2006. If it gets hot enough to melt 95/5 thats going to be the least of his problems. As an experiment I changed the setting to 3 CPH (the next higher option), and this has evened out the room temp fluctuation considerably, and results in less extreme radiator temps. With 3 CPH, I measure on average 23-26 minutes of down time between cycles, and 6-8 minutes of firing (making steam after ~2 minutes) per cycle.Weil McLain Ultra 155 will not light off because it is not getting fuel. The boiler will not light off. I have air flow and spark but no fuel. I can see the blue arc if the igniter through the view port and hear the relay click. Both fuses are good on the control board.Recessed Cast Iron Radiators. I'm in the market for a house, and many of the houses I'm looking at were built in the 1930's and have recessed cast iron radiators. These radiators are gorgeous, very compact (since they are recessed) and appear to be good candidates for a modern gas condensing boiler with outdoor reset.. Sneaky snake song